Daikin 25C Qualifying Equipment




Daikin 2023-2032 25C Qualifying Models Flyer





Daikin 2023-2032 25C Qualifying Models 

  January 1, 2023 – December 31, 2032
Limit 30% of installed cost up to capped amount
Total Claim
Tax credit parameters indicate a $2,000 tax credit for heat pumps. In addition, there is a $1,200 aggregate yearly tax credit maximum for all building envelope components, home energy audits, and energy property, for a total maximum up to $3,200.
Equipment Criteria
Highest CEE efficiency tier (not including any advanced tier) when placed into service.
NOTE: Criteria not static and will change if CEE amends criteria.
Tax CreditEquipment TypeMinimum EfficiencyEligible Products-
$2000Air Source Heat Pump


 Ducted – South and SouthwestCEE TIER 1
HSPF2 ≥ 7.8
EER2 ≥ 11.7
SEER2 ≥ 15.2
DZ4SQ, DZ4SE, DZ5SE,
DZ7TC, DZ9VC, RZQ

Ducted – NorthCEE TIER 1
HSPF2 ≥ 8.1
EER2 ≥ 10.0
SEER2 ≥ 15.2
DZ6VS, DZ7TC, DZ9VC, RZQ,
RXL, MXL, MXS
COP at 5°F ≥ 1.75
Capacity Ratio
≥ 58% at 17°F/47°F
OR
≥ 70% at 5°F/47°F
Ductless – South and SouthwestCEE TIER 2
HSPF2 ≥ 9.0
EER2 ≥ 12.0
SEER2 ≥ 16.0
RX_A, RX_B, RXL, RXM, RXS,
RX_R, RZQ, RXTQ, RXSQ

Ductless – NorthCEE TIER 2
HSPF2 ≥ 9.5
EER2 ≥ 9.0
SEER2 ≥ 16.0
RX_A, RX_B, RXL, RXM, RXS,
RX_R, RZQ, MXL, MXS
COP at 5°F ≥ 1.75
Capacity Ratio
≥ 58% at 17°F/47°F
OR
≥ 70% at 5°F/47°F
$2000Package System Air Source Heat Pump



SouthCEE TIER 1
HSPF2 ≥ 7.2
EER2 ≥ 10.6
SEER2 ≥ 15.2
TBD
NorthCEE TIER 1
HSPF2 ≥ 8.1
EER2 ≥ 10.0
SEER2 ≥ 15.2
TBD COP at 5°F ≥ 1.75
Capacity Ratio
≥ 58% at 17°F/47°F
OR
≥ 70% at 5°F/47°F
$600Split System Central Air ConditionerCEE Tier 2
SEER2 ≥ 16.0
EER2 ≥ 12.0
DX5SE, DX7TC, DX9VC, RZR,
RK_A, RK_B

$600Package System Central ACCEE Tier 1
SEER ≥ 15.2
EER ≥ 11.5
TBD
$600Gas, Propane or Oil Furnace and FansCEE Tier 3
AFUE ≥ 97%
DC97MC, DM97MC
$600
Improvements or replacement of panelboard, subpanel board, branch circuits



$150Qualified Home Energy Audits


Daikin 2022 25C Qualifying Models 

Equipment Type2022 Tax CreditMinimum Efficiency25C Eligible Daikin Products (2022)
Split System Air Source Heat Pump$300HSPF≥8.5
EER≥12.5
SEER≥14
DZ14SN, DZ14SA, DZ16SA, DZ16TC, DZ18TC, DZ18VC, DZ20VC
Ductless Heat Pump$300HSPF≥8.5
EER≥12.5
SEER≥15
2MXL, 3MXL, 4MXL, RX**AX, RX**NM, RX**QM, RX**RM, RXG, RXL, RXM, RXS, RXSQ
Ductless Air Conditioner$300SEER≥16
EER≥13
RZR
Split System Air Conditioner$300SEER≥16
EER≥13
DX5SE, DX7TCA, DX16SA, DX16TC, DX17VS, DX18TC, DX20VC
Package System Air Source Heat Pump$300HSPF≥8
EER≥12
SEER≥14
DP14HH, DP16HH, DP16HM, DRH, DSH, DTH
Package System Central Air Conditioner$300EER≥12
SEER≥14
DP14CH, DP15CH, DRC, DSC, DTC
Package System Dual-Fuel$300HSPF≥8
EER≥12
SEER≥14
DP14DM
Gas Furnace$150AFUE≥95%DC96VC, DC97MC, DM96VC, DM96VE, DC96SN, DC96TN, DC96VC, DC97MC, DM96SC, DM96SN, DM96TN, DM97MC
Equipment Containing Advanced Main Circulating Fan$50Uses no more than 2% of total energyDC80SN, DC80TN, DC80VC, DM80SE, DM80SN, DM80VC, DC96VC, DC97MC, DM96VC, DM96VE, DM97MC, DBG, DFG, DRG, DP14DM, DP14GM, DP14UM, DP16GM, DP16UM, DP3UM
* This information does not and should not be considered tax advice. All information is for general purposes only. Contact your tax professional for specific, applicable details.

** Criteria not static and will change if CEE amends criteria.

*** For further details, see CEE Residential Electric HVAC Specification - January 1, 2023