January 1, 2023 – December 31, 2032 | |
---|---|
Limit | 30% of installed cost up to capped amount |
Total Claim | Tax credit parameters indicate a $2,000 tax credit for heat pumps. In addition, there is a $1,200 aggregate yearly tax credit maximum for all building envelope components, home energy audits, and energy property, for a total maximum up to $3,200. |
Equipment Criteria | Highest CEE efficiency tier (not including any advanced tier) when placed into service. NOTE: Criteria not static and will change if CEE amends criteria. |
Tax Credit | Equipment Type | Minimum Efficiency | Eligible Products | - |
---|---|---|---|---|
$2000 | Air Source Heat Pump | |||
Ducted – South and Southwest | CEE TIER 1 HSPF2 ≥ 7.8 EER2 ≥ 11.7 SEER2 ≥ 15.2 | ASZH5, ASZN4, ASZH4, ASZC7, ASZV9, RZQ, MXL, MXS | ||
Ducted – North | CEE TIER 1 HSPF2 ≥ 8.1 EER2 ≥ 10.0 SEER2 ≥ 15.2 | ASZS6, ASZC7, ASZV9, RZQ, RXL | COP at 5°F ≥ 1.75 Capacity Ratio ≥ 58% at 17°F/47°F OR ≥ 70% at 5°F/47°F | |
Ductless – South and Southwest | CEE TIER 2 HSPF2 ≥ 9.0 EER2 ≥ 12.0 SEER2 ≥ 16.0 | RX_A, RX_B, RXL, RX_B, RXL, RXM, RXS, RX_R, RZQ, RXTQ, RXSQ | ||
Ductless – North | CEE TIER 2 HSPF2 ≥9.5 EER2 ≥ 9.0 SEER2 ≥ 16.0 | RX_A, RX_B, RXL, RX_B, RXL, RXM, RXS, RX_R, RZQ, MXL, MXS | COP at 5°F ≥ 1.75 Capacity Ratio ≥ 58% at 17°F/47°F OR ≥ 70% at 5°F/47°F | |
$2000 | Package System Air Source Heat Pump | |||
South | CEE TIER 1 HSPF2 ≥ 7.2 EER2 ≥ 10.6 SEER2 ≥ 15.2 | TBD | ||
North | CEE TIER 1 HSPF2 ≥ 8.1 EER2 ≥ 10.0 SEER2 ≥ 15.2 | TBD | COP at 5°F ≥ 1.75 Capacity Ratio ≥ 58% at 17°F/47°F OR ≥ 70% at 5°F/47°F | |
$600 | Split System Central Air Conditioner | CEE Tier 2 SEER2 ≥ 16.0 EER2 ≥ 12.0 | ASXH5, ASXC7, ASXV9, RZR, RK_A, RK_B | |
$600 | Package System Central Air Conditioner | CEE Tier 1 SEER ≥ 15.2 EER ≥ 11.5 | TBD | |
$600 | Gas, Propane or Oil Furnace and Fans | CEE Tier 3 AFUE ≥ 97% | ACVM97, AMVM97 | |
$600 | Improvements or replacement of panelboard, subpanel board, branch circuits | |||
$150 | Qualified Home Energy Audits |
Equipment Type | 2022 Tax Credit | Minimum Efficiency | 25C Eligible Amana brand Products (2022) |
---|---|---|---|
Split System Air Source Heat Pump | $300 | HSPF≥8.5 EER≥12.5 SEER≥14 | ANZ14, ASZ14, ASZ16, ASZC16, ASZC18, ASZC20, DSZC16, DSZC18, GSZ14, GSZ16, GSZC16, GSZC18, GVZC20, VSZ14 |
Split System Air Conditioner | $300 | SEER≥16 EER≥13 | ASX16, ASXC16, ASXC18, ASXC7, ASXH5, AVXC2, GSX16, GSX16S, GSXC16, GSXC18, GVXC20 |
Package System Air Source Heat Pump | $300 | HSPF≥8 EER≥12 SEER≥14 | APH14, APH16, GPH14, GPH16 |
Package System Central Air Conditioner | $300 | EER≥12 SEER≥14 | APC14, GPC14, GPC15 |
Package System Gas/Electric | $300 | HSPF≥8 EER≥12 SEER≥14 | APC14, GPC14, GPC15 |
Package System Dual-Fuel | $300 | HSPF≥8 EER≥12 SEER≥14 | APD14, GPD14 |
Gas Furnace | $150 | AFUE≥95% | AC9C96, AC9S96, ACVC96, ACVM97, AM9C96, AM9S96, AMEC96, AMES96, AMVC96, ANVM97, AMVS96 |
Equipment Containing Advanced Main Circulating Fan | $50 | Uses no more than 2% of total energy | AC9C80, AC9S80, ACES80, ACVC80, AM9S80, AMES80, AMES92, AMVC80, ACVC96, ACVM97, AMEC96, AMES96, AMVC96, AMVM97, APD14, APG14, APG16, APGM3, APU14, APUM3 |